Sign In | Join Free | My burrillandco.com
Home > Thermocouple Compensating Wire >

PTFE PFA FEP J K T Type Thermocouple Extension Cable Wire Copper Heating Insulated

    Buy cheap PTFE PFA FEP J K T Type Thermocouple Extension Cable Wire Copper Heating Insulated from wholesalers
     
    Buy cheap PTFE PFA FEP J K T Type Thermocouple Extension Cable Wire Copper Heating Insulated from wholesalers
    • Buy cheap PTFE PFA FEP J K T Type Thermocouple Extension Cable Wire Copper Heating Insulated from wholesalers
    • Buy cheap PTFE PFA FEP J K T Type Thermocouple Extension Cable Wire Copper Heating Insulated from wholesalers
    • Buy cheap PTFE PFA FEP J K T Type Thermocouple Extension Cable Wire Copper Heating Insulated from wholesalers
    • Buy cheap PTFE PFA FEP J K T Type Thermocouple Extension Cable Wire Copper Heating Insulated from wholesalers

    PTFE PFA FEP J K T Type Thermocouple Extension Cable Wire Copper Heating Insulated

    Ask Lasest Price
    Brand Name : Victory
    Model Number : K,N,E,J,T,B,R,S Types
    Certification : CE,ROHS,ISO 9001
    Payment Terms : L/C, T/T, Western Union, MoneyGram
    Supply Ability : 300 tons per month
    Delivery Time : 5-21 days
    • Product Details
    • Company Profile

    PTFE PFA FEP J K T Type Thermocouple Extension Cable Wire Copper Heating Insulated

    Thermocouple Extension Wire is a cable designed to extend thermocouple signals and can be used with a variety of thermocouple types, including Type K, Type N, Type E, Type J, Type T, Type B, Type R, and Type S . It provides reliable signal transmission and temperature measurement solutions and is commonly used in industrial control systems, laboratory testing and temperature monitoring applications. Thermocouple Extension Wire has good linear characteristics and anti-interference ability, can accurately transmit the weak voltage signal generated by the thermocouple, and maintain the stability and accuracy of the signal. Whether performing high-temperature furnace control, chemical process monitoring, or laboratory temperature measurement, Thermocouple Extension Wire provides reliable signal transmission to ensure the accuracy and reliability of temperature monitoring systems.


    Thermocouple Wire

    Code Wires component of the thermocouple
    +Positive leg -Negative leg
    N Ni-cr-si (NP) Ni-si-magnesium (NN)
    K Ni-Cr (KP) Ni-Al(Si) (KN)
    E Ni-Cr (EP) Cu-Ni<constantan> (EN)
    J Iron (JP) Cu-Ni<constantan> (JN)
    T Copper (TP) Cu-Ni<constantan> (TN)

    ​Standards

    ASTM ANSI IEC DIN BS NF JIS GOST
    (American Society for Testing and Materials) E 230 (American National Standard Institute) MC 96.1 (European Standard by the International Electrotechnical Commission 584)-1/2/3 (Deutsche Industrie Normen) EN 60584 -1/2 (British Standards) 4937.1041, EN 60584 - 1/2 (Norme Française) EN 60584 -1/2 - NFC 42323 - NFC 42324 (Japanese Industrial Standards) C 1602 - C 1610 (Unification of the Russian Specifications) 3044

    Thermocouple No. indexing Compensation wire type Usag Classification Measuring junction temperature / ℃ standard EMF value/μV Precision grade General grade
    Tolerance μV Thermal EMF range μV Tolerance μV Thermal EMF range μV
    SorR SC or RC G 100 646 ±30 616~676 ±60 586~706
    H 100 646 - - ±60 586~706
    200 1 1441 - - 1.381~1 501
    K KX,KCA G -25 -968 ±40 -924~-1 012 ±80 -880~-1 056
    or KCB 100 4 096 4 052~4 140 4 008~4 184
    H -25 -968 ±40 -924~-1 012 ±88 -880~-1 056
    100 4 096 4 052~4 140 4 008~4 184
    200 8 138 8 094~8 182 8 050~8 226
    N NX or NC G -25 -646 ±43 -603~-689 ±86 -560~-732
    100 2 774 2 731~2 817 2 688~2 860
    H -25 -646 ±43 -603~-690 ±86 -560~-732
    100 2 774 2 731~2 817 2 688~2 860
    200 5 913 5 870~5 956 5 827~5 999
    E EX G -25 -1 432 ±81 -1 351~-1 513 ±138 -1 294~-1 570
    100 6 319 6 238~ 6400 6 181~6 457
    H -25 -1 432 ±81 -1 351~- 1513 ±138 -1 294~-1 570
    100 6 319 6 238~6 400 6 181~6 457
    200 13 421 13 340~13 502 13 283~13 559
    J JX G -25 -1 239 ±62 -1 177~-1 301 ±123 -1 116~-1 362
    100 5 269 5 207~5 331 5 146~5 392
    H -25 -1 239 ±62 - 177~-1 301 ±123 -1 116~-1 362
    100 5 269 5 207~5 331 5 146~5 392
    200 10 779 10 717~10 841 10 656~10 902
    T TX G -25 -940 ±30 -910~-970 ±60 -850~-1 000
    100 4 279 4 249~4 309 4 189~4 339
    H -25 -940 ±48 -892~-988 ±90 -850~-1 030
    100 4 279 4231~4 327 4 189~4 369
    200

    Calibration of thermocouple
    Model number of Compensation cable
    Alloy wire name of Compensation cable
    S or R
    SC or RC
    Cu-CuNi
    K
    KC
    Cu-CuNi
    KX
    NiCr-NiSi
    N
    NC
    Fe-CuNi
    NX
    NiCrSi-NiSiMg
    E
    EX
    NiCr-CuNi
    J
    JX
    Fe-CuNi
    T
    TX
    Cu-CuNi
    PTFE PFA FEP J K T Type Thermocouple Extension Cable Wire Copper Heating Insulated
    PTFE PFA FEP J K T Type Thermocouple Extension Cable Wire Copper Heating Insulated
    PTFE PFA FEP J K T Type Thermocouple Extension Cable Wire Copper Heating Insulated
    PTFE PFA FEP J K T Type Thermocouple Extension Cable Wire Copper Heating Insulated PTFE PFA FEP J K T Type Thermocouple Extension Cable Wire Copper Heating Insulated

    Quality PTFE PFA FEP J K T Type Thermocouple Extension Cable Wire Copper Heating Insulated for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Changzhou Victory Technology Co., Ltd
    *Subject:
    *Message:
    Characters Remaining: (0/3000)